Why a connection is refused
The three messages UnifCAD shows when it rejects a wire, what can connect to what, and how terminal numbers really work.
When a wire cannot be created, UnifCAD does not fail silently: a short badge appears with the reason. There are three.
"A cable already exists between those two points"
Those two terminals are already joined. A second identical wire would add nothing to the circuit and would sit invisibly on top of the first one.
If what you actually want is a second path — for example feeding a third device from the same point — draw the wire onto the existing run instead of onto the terminal. That creates a junction and a branch. See branching.
"The pin reached its maximum number of connections"
A terminal is a physical screw, and it takes a limited number of conductors. When it is full, the answer is not to force another wire in — it is to splice: run the new wire onto the conductor that already leaves that terminal.
That is what an electrician does with a terminal block, and it is what the junction represents.
"Incompatible connection: AC and DC cannot be joined"
One end belongs to an AC system and the other to a DC one. This is refused on purpose: joining them is not a drawing mistake you can shrug off, it is a short between two supplies.
Check which supply feeds each side of the sheet. A 24 V DC control circuit fed from a power supply and a 230/400 V AC power circuit are two separate systems, and they meet only through a device that is built to bridge them — a relay coil, a contactor, a PLC input.
Terminal numbers: the label is not the identity
Every numbered contact block carries a number — 13-14, 21-22, 23-24. In
UnifCAD that number follows EN 50005:
- the tens digit is the position of the block in the device,
- the units digit is its function:
1-2for a normally closed contact,3-4for a normally open one.
So the second auxiliary block of -KM1 is 23-24, not a second 13-14.
Renumbering a block never breaks the circuit
Conduction is decided by the block itself, not by the text printed on it. You can renumber a contact and it keeps conducting exactly as before. The number is documentation — correct documentation, but documentation.
Changing a number
Open the component and go to the Terminal numbers section.
- Type the numbers you want. A blank field is a valid answer: it means "the catalog number".
- Next free block fills in the next unused block —
23-24, then33-34— in one click. - What you write stays written. Renaming the device, moving it to another device, or reordering the sheet will not renumber it behind your back.
Repeated numbers are allowed: two blocks bought separately both arrive stamped
13-14, and that is a legitimate drawing.
Terminals whose number is their meaning are not editable, because changing
them would be wrong rather than merely unusual: the 95-96 / 97-98 of a
thermal relay, and the timed contacts of a timing relay.